Add: No.2, Huashi Road, Gangkou Town, Zhongshan, Guangdong 528400, China
        Tel:0086)760-88787946 88711407
        Fax:(0086)760-88789586

        E-mail : export@sfyb.com.cn
        • Name: SF-101(16A)

        Features 
        Temperature Display
        Temperature Control
        Value Storing
        Parameter Locking
        Self Testing
         
        Technical Data 
        Range of temperature displayed:-45℃~99℃(-40~120℉)
        Range of set temperature:-45℃~99℃(-40~120℉)
        Accuracy:±1℃  (±2℉)
        Compressor: N.O. 16A/250VAC
        Dimension:77(Length)×35(Width)×60(Depth)mm
        Mounting hole dimension:71(Length)×29(Width)mm 

        Parameters 

        Paramete
        Function
        Set range
        Default
        E1
        Lower setpoint limit
        -45℃/-40℉~Set temp.
        -35℃/-31℉
        E2
        Higher setpoint limit
        Set temp.~99℃/120℉
        20℃/68℉
        E3
        Temp.hysteresis
        1~30℃/1~54℉
        4℃/7℉
        E4
        Comp.start delay time
        0~10Min
        2Min
        E5
        Offset on room temp.
        -20~20℃/℉
        0
        C1
        Temperature unit
        0=℃   1=℉
        0
        F1
        Max.Defrost duration
        1~90Min
        20Min
        F2
        Defrost interval time
        0~24Hr
        0
        F4
        Display termination temp.
        0=Normal display
        1=Last value before defrost
        1
         

        Download instructions: SF-101(16A) 【查看】